  confidential document page: 1 /21 data image corporation lcd module specification item no.: tg322450gncwa-01 table of contents 1. cover & contents ??????????????????????????????????????????????? 1 2. record of revision ????????????????????????????????????????????? 2 3. general specifications ?????????????????????????????????????? 3 4. absolute maximum ratings ?????????????????????????????? 4 5. electrical characteristics ?????????????????????????????? 5 6. electro-optical characteristic ?????????????????????? 5 7. timing characteristics ????????????????????????????????????? 8 8. pin connections ???????????????????????????????????????????????????? 12 9. power supply ??????????????????????????????????????????????????????? 12 10. block diagram ?????????????????????????????????????????????????????? 13 11. quality assurance ????????????????????????????????????????????? 14 12. lot numbering system ??????????????????????????????????????? 18 13. lcm numbering system ??????????????????????????????????????? 18 14. precautions in use lcm ?????????????????????????????????????? 19 15. outline drawing ?????????????????????????????????????????????????? 20 16. package information ??????????????????????????????????????????? 21 r&d dept. q.c. dept. eng. dept. prod. dept. version: issued date: sheet code: total pages: 2003/8/5 21
confidential document page: 2 /21 2. record of revision rev date item page comment
confidential document page: 3 /21 3. general specification display format : 320 dots (w) 240 (h) dots dot size : 0.339 (w) 0.338 (h) mm dots pitch : 0.354 (w) 0.353 (h) mm view area : 116.08 (w) 87.51 (h) mm outline dimensions : 126.5 (w) 100 (h) 6.8 (t) mm max. weight : 125g max. v lcd type : stn stn yellow fstn tn polarizer mode : reflective transflective v transmissive negative v view angle : 6 o?clock 12 o?clock others v backlight : led el ccfl backlight color : yellow green amber blue v white others controller / driver : nt7701/nt7702 v normal wide temperature operating 0 to 50 c operating -20 to 70 c temperature range : storage -20 to 70 c storage -30 to 80 c
confidential document page: 4 /21 4. absolute maximum ratings 4.1 electrical absolu te maximum ratings v ss = 0v, ta = 25 c item symbol min. max. unit supply voltage (logic) v dd -v ss -0.3 6.0 v supply voltage (lcd driver) v o -v ss 0 30 v input voltage v i v ss v dd v operating temperature t op 0 50 c storage temperature t stg -20 70 c 4.2 environmental abso lute maximum ratings operating storage item (min.) max.) (min.) (max.) comment ambient temp 0 50 -20 70 note (1) humidity note (2) note(2) without condensation vibration -- 4.9m/s 2 -- 19.6m/s 2 xyz direction shock -- 29.4m/s 2 -- 490m/s 2 xyz direction note(1) ta = 0 c : 50hr max. note(2) ta 40 c : 90% rh max. ta 40 c : absolute humidity must be lower than the humidity of 90% rh at 40 c .
confidential document page: 5 /21 5. electrical characteristics item symbol condition min. typ. max. unit supply voltage (logic) v dd -v ss 3.0 3.3 5.5 v 0 c 21.7 22.2 22.7 25 c 21.3 22 22.7 supply voltage (lcd) v o -v ss 50 c 20.9 21.4 21.9 v v ih 0.8*vdd -- v dd input voltage v il -- vss -- 0.2*vdd v logic supply current i dd v dd -v ss= 3.3v -- 10 -- ma 6. electro-optica l characteristics item symbol condition min. typ. max. unit ref. 0 c 900 1200 rise time tr 25 c -- 210 250 ms 0 c 990 1500 fall time tf 25 c -- 220 270 ms note (1) contrast cr 25 c 7 10 -- note (3) -- 45 -- view angle 1 ~ 2 ? 1, ? 2 25 c & cr 2 -- 40 -- note (2) frame frequency ff 25 c 60 75 80 hz brightness 350 400 -- nit uniformity = 0 75 80 % note (1) & (2) : see next page note (3) : contrast ration is defined under the following condition: cr= brightness of non-selected condition brightness of selected condition ( a ). temperature ---------- 25 c ( b ). frame frequency ---- 75hz ( c ). viewing angle -------- = 0 , ? = 0 ( d ). operating voltage --- 22.0v
confidential document page: 6 /21 note (1) response time is measured as the shortest period of time possible between the change in state of an lcd segment as demonstrated below: +vop 1/f f 0 -vop 90% 100% 10% t r t f condition: ( a ) . temperature ---------------25 c ( b ) . frame frequency --------- 75hz ( c ) . view angle ----------------- = 0 , ? =0 ( d ) . operating voltage --------22.0v note (2) definition of view angle top ? bottom direction right -- left direction top ? 2 ? 1 1 2 bottom left right
confidential document page: 7 /21 6.1 ccfl electrical characteristic item condition start voltage 500 vrms min,at ta=25 c tube voltage 300vrms typ,at ta=25 c tube current 5m arms typ ,at ta=25 c drive frequency 55 khz , typ at ta=25 c 6.1.2 environmental conditions item temperature humidity unit operating 0 to 50 c 0 to 90% rh storage -20 to 70 c 0 to 90% rh recommend ccfl inverter: tdk l10l operation voltage +12v , 300ma tdk l10a operation voltage +5v , 600ma
confidential document page: 8 /21 7. timing characteristic segment timing: item symbol condition min. typ. max. units shift clock period *1 twck tr,tf 10ns 125 ns shift clock pulse width twckh twckl 51 ns data set up time tds 30 ns data hold time tdh 40 ns latch pulse ?h? pulse width twlph 51 ns shift clock rise to latch pulse rise time tld 0 ns shift clock fall to latch pulse fall time tsl 51 ns latch pulse rise to shift clock rise time tls 51 ns latch pulse fall to shift clock fall time tlh 51 ns input signal rise/ fall time *2 tr, tf 50 ns enable setup time ts 36 ns dispoffb removal time tsd 100 ns dispoffb ?l? pulse width twdl 1.2 u output delay time (1) td cl=15pf 78 ns output delay time (2) tpd1, tpd2 cl=15pf 1.2 us output delay time (3) tpd3 cl=15pf 1.2 us note: *1. take the cascade connection into consideration. *2. (twck-twckh-twckl)/2 is maximum in the case of high speed operation.
confidential document page: 9 /21 twlph cl1 (lp) tsl tld tls tlh twckh twckl cl2 (xck) tr tf twck tds tdh db0~db7 (di0-di3) last data top data twdl tsd /disp off (dispoff) segment timing m tpd1 cl1 ( lp ) tpd2 /disp off (dispoff) tpd3 y1~y240
confidential document page: 10 /21 common timing: item symbol condition min. typ. max. units shift clock period twlp tr,tf 20ns 250 ns vdd=+5.0v 10% 15 ns pulse ?h? pulse width twlph vdd=+2.5v~+4.5v 30 data set up time tsu 30 ns data hold time th 50 ns input signal rise/ fall time tr, tf 50 ns dispoffb removal time tsd 100 ns dispoffb ?l? pulse width twdl 1.2 u output delay time (1) tdl cl=15pf 200 ns output delay time (2) tpd1, tpd2 cl=15pf 1.2 us output delay time (3) tpd3 cl=15pf 1.2 us twlp twlph tr cl1 tsu th tf eio2 tdl ei01 tsd /disp off (disp off) twdl common timing
confidential document page: 11 /21 7.1 timing chart m ( 37.5hz) 1/ff flm (75h z ) 240 1 2 240 1 2 240 1 2 cl1 frame cl1 cl2 cl2 x ( 320 / 8bit (4bit)) pulse db0-db7 (db0~db4)
confidential document page: 12 /21 8 pin connections no symbol function 1 vdd logic power input, +3.3v 2 vss 0v 3 / disp off display on/off control input, high =on, low =off 4 cl1 data latch pulse. 5 cl2 data shift pulse. 6 flm first line mark.(75h z ) 7 m switch signal to convert lcd drive wave form into ac(37.5h z ) 8 dbo input data signal 0 9 db1 input data signal 1 10 db2 input data signal 2 11 db3 input data signal 3 12 v0 13 v1 14 v2 15 v3 16 v4 lcd driving voltage 17 md data bus bit selection, low = 4bits(db0~db3), high =8bits (db0~db7) 18 db4 input data signal 4 19 db5 input data signal 5 20 db6 input data signal 6 21 db7 input data signal 7 22 gnd 23 gnd 24 gnd 25 gnd ground ccfl backlight no. symbol i/o description remark 1 hot i power supply for backlight unit (high voltage) 2 gnd - ground for backlight unit 9. power supply vdd vdd vee1 vo v0 r1 + v1 lcd r2 v2 module r3 v3 r4 v4 r5 x4 c2 c3 c4 c5 c6 c1 gnd vss,gnd q1: 2sc1815 r1=r2=r4=r5=18k ? ;r3=160k ? (1/13 bias) op-amp: ba10324 c1=o.iuf;c2=c3=c4=c5=c6=3.3uf -
confidential document page: 13 /21 10. block diagram db7 db6 db5 ?? db2 db1 db0 com driver lcd panel 320 x 240 dots hot gnd seg driver ccfl back light flm cl1 m vdd vss v3 /di sp off v2 vo v1 v4 cl2 md db0 ~ db7 seg1 seg320 c om1 c om240
confidential document page: 14 /21 11. quality assurance 11.1 test condition 11.1.1 temperature and humidity(ambient temperature) temperature : 20 5 c humidity : 65 5% 11.1.2 operation unless specified otherwise, test will be conducted with lcm in operation. 11.1.3 container unless specified otherwise, vibration te st will be conducted on module only. 11.1.4 test frequency single cycle. 11.1.5 test method no. parameter conditions regulations 1 high temperature operating 50 2 c note 3 2 low temperature operating 0 2 c note 3 3 high temperature storage 70 2 c note 3 4 low temperature storage -20 2 c note 3 5 vibration test (non-operation state) total fixed amplitude : 1.5mm vibration frequency : 10 ~ 55hz one cycle 60 seconds to 3 directions of x.y.z. for each 15 minutes note 3 6 damp proof test (non-operation state) 40 c 2 c, 90~95%rh, 96h note 1,2 7 shock test (non-operation state) to be measured after dropping from 60cm high once concrete surface in packing state note 3 note 1: returned under normal temperature and humidity for 4 hrs. note 2: no dew condensation to be observed. note 3: no change on display and in operation under the test condition
confidential document page: 15 /21 11.2 inspectio n condition 11.2.1 inspection conditions the lcd shall be inspected under 40w white fluorescent light. 45 11.2.2 definition of applicable zones b lcd a bezel pcb a : display area b : non-display area
confidential document page: 16 /21 11.2.3 inspection parameters no. parameter criteria 1 black or white spots acceptable number zone dimension a b class of defects aql level d < 0.15 ? ? 0.15 d< 0.2 4 4 0.2 d 0.25 2 2 d 0.3 0 1 minor 2.5 d = (long + short) / 2 * : disregard 2 scratch, substances acceptable number x (mm) zone y(mm) a b class of defects aql level ? 0.04 w ? ? 3.0 l 0.06 w 4 4 2.0 l 0.08 w 2 3 ? 0.1 < w 0 1 minor 2.5 x : length y : width ? : disregard total defects should not exceed 4/module 3 air bubbles (between glass & polarizer) acceptable number zone dimension a b class of defects aql level d 0.15 ? ? 0.15 < d 0.25 2 ? 0.25 < d 0 1 minor 2.5 ? : disregard total defects shall not excess 3/module. 4 uniformity of pixel (1) pixel shape (with dent) 0.152
confidential document page: 17 /21 4 uniformity of pixel (2) pixel shape ( with projection) should not be connected to next pixel 0.01 (3) pin hole x y ( x + y )/2 0.02mm (less than 0.1 mm is no counted) (4) deformation x ( x + y ) / 2 0.3mm y total acceptable number : 1/pixel, 5/cell definition major aql 0.65% it is a defect that is likely to result in failure or to reduce materially the usab ility of the product for the intended function. aql 1.00% it is a defect that is likely to assembly size and not result in functioning problem. class of defects minor aql 2.5% it is a defect that will not result in functioning problem with deviation classified. 11.3 sampling condition unless otherwise agree in written, the sampling inspection shall be applied to the incoming inspection of customer. lot size: quantity of shipment lot per model. sampling type: normal inspection, single sampling sampling table: mil-std-105e inspection level: level ii
confidential document page: 18 /21 13. lot numbering system 9 7 4 2 production week number production year 14. lcm numbering system tg 322450 g n c w a ?01 version :01 view direction & temp. range a?bottom view 6h & normal temp. b?bottom view 6h & wide temp. c?top view & normal temp. d?top view & wide temp. backlight color g ?green w ?white n ?none backlight s ?edge light led b/l e ?el c?ccfl back light mode m ? transmissive r ? reflective f ? transflective n - negative lcd type f ? fstn s ?stn p ? fstn paper white series code 3224 50 ?240 dots x 320 dot, 5 lcd type, 0 pcb type model type cm ? character module gx ? custom graphic module tg?slim tab/cog module tx?custom slim tab/cog module
confidential document page: 19 /21 15. precaution for using lcm 1. liquid crystal display (lcd) lcd is made up of glass, organic sealant, organic fluid, and polymer based polarizers. the following precautions should be taken when handing, (1). keep the temperature within range of use and storage. excessive temperature and humidity could cause polarization degredation, polarizer peel off or bubble. (2). do not contact the exposed polarizers with anything harder than an hb pencil lead. to clean dust off the display surface, wipe gently with cotton, chamois or other soft material soaked in petroleum benzin. (3). wipe off saliva or water drops immediately. contact with water over a long period of time may cause polarizer deformation or color fading, while an active lcd with water condensation on its surface will cause corrosion of ito electrodes. (4). glass can be easily chipped or cracked from rough handling, especially at corners and edges. (5). do not drive lcd with dc voltage. 2. liquid crystal display modules 2.1 mechanical considerations lcm are assembled and adjusted with a high degree of precision. avoid excessive shocks and do not make any alterations or modifications. the following should be noted. (1). do not tamper in any way with the tabs on the metal frame. (2). do not modify the pcb by drilling extra holes, changing its outline, moving its components or modifying its pattern. (3). do not touch the elastomer connector, especially insert an backlight panel (for example, el). (4). when mounting a lcm make sure that the pcb is not under any stress such as bending or twisting . elastomer contacts are very delicate and missing pixels could result from slight dislocation of any of the elements. (5). avoid pressing on the metal bezel, otherwise the elastomer connector could be deformed and lose contact, resulting in missing pixels. 2.2. static electricity lcm contains cmos lsi?s and the same precaution for such devices should apply, namely (1). the operator should be grounded whenever he/she comes into contact with the module. never touch any of the conductive parts such as the lsi pads, the copper leads on the pcb and the interface terminals with any parts of the human body. (2). the modules should be kept in antistatic bags or other containers resistant to static for storage. (3). only properly grounded soldering irons should be used. (4). if an electric screwdriver is used, it should be well grounded and shielded from commutator sparks. (5) the normal static prevention measures should be observed for work clothes and working benches; for the latter conductive (rubber) mat is recommended. (6). since dry air is inductive to statics, a relative humidity of 50-60% is recommended. 2.3 soldering (1). solder only to the i/o terminals. (2). use only soldering irons with proper grounding and no leakage. (3). soldering temperature : 280 c 10 c (4). soldering time: 3 to 4 sec. (5). use eutectic solder with resin flux fill. (6). if flux is used, the lcd surface should be covered to avoid flux spatters. flux residue should be removed after wards. 2.4 operation (1). the viewing angle can be adjusted by varying the lcd driving voltage v0. (2). driving voltage should be kept within specified range; excess voltage shortens display life. (3). response time increases with decrease in temperature. (4). display may turn black or dark blue at temperatures above its operational range; this is (however not pressing on the viewing area) may cause the segments to appear ?fractured?. (5). mechanical disturbance during operation (such as pressing on the viewing area) may cause the segments to appear ?fractured?. 2.5 storage if any fluid leaks out of a damaged glass cell, wash off any human part that comes into contact with soap and water. never swallow the fluid. the toxicity is extremely low but caution should be exercised at all the time. 2.6 limited warranty unless otherwise agreed between data image and customer, data image will replace or repair any of its lcd and lcm which is found to be defective electrically and visually when inspected in accordance with data image acceptance standards, for a period on one year from date of shipment. confirmation of such date shall be based on freight documents. the warranty liability of data image is limited to repair and/or replacement on the terms set forth above. data image will not responsible for any subsequent or consequential events.
confidential document page: 20 /21 16. outline drawing
confidential document page: 21 /21 17. package in formation anti-static bag module


▲Up To Search▲   

 
Price & Availability of TG322450GNCWA01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X